Hoist motor
Lifts the load vertically and must handle gravity load, starting torque, holding brake integration and frequent starts.
Motor kW is only the first check. A crane motor must also match duty, starts per hour, torque, speed, brake, gearbox, control method, ambient conditions and protection requirements.
A crane motor should not be selected only from calculated kW. Ask the supplier to confirm kW, speed, torque, duty, starts per hour, insulation class, enclosure, ambient rating, brake/VFD compatibility, service factor and datasheet for each motion.
A hoist motor, cross-travel motor and long-travel motor may all be called "crane motors," but they face different loading and control problems.
Lifts the load vertically and must handle gravity load, starting torque, holding brake integration and frequent starts.
Moves the trolley/hoist across the bridge. Acceleration, positioning and smoothness often matter more than steady power.
Moves the complete bridge along runway rails. It is sensitive to skew, rail alignment, wind, friction and synchronization.
| Motor item | Ask the supplier to state | Why it matters | Red flag |
|---|---|---|---|
| Motor make and model | Manufacturer, frame size, rated kW, rpm, mounting and datasheet. | Confirms whether two offers use comparable equipment. | Only "standard motor" stated. |
| Duty and thermal rating | Duty designation, starts/hour, insulation class, temperature rise and ambient rating. | Prevents overheating and premature winding failure. | No starts/hour or duty basis. |
| Torque capability | Starting torque, pull-out torque, VFD low-speed torque and margin basis. | Crane motors need torque, not just kW. | Only steady-state kW calculation provided. |
| Protection and enclosure | IP rating, cooling method, terminal box position, cable entry and hazardous/corrosive suitability if needed. | Wrong enclosure causes environmental and maintenance failures. | Outdoor/dust/corrosion environment ignored. |
| Brake and control interface | Brake type, rectifier/control sequence, VFD compatibility, DBR/regenerative braking scope. | Motor, brake and drive must work as one system. | Brake/VFD responsibility split between vendors. |
Calculated kW can be acceptable while torque, thermal rating or starts/hour are still wrong.
A light-duty motor in a frequent-cycle crane can overheat even if the capacity appears correct.
The motor, brake, rectifier, contactor/VFD and emergency stop sequence must be compatible.
Dust, heat, outdoor use, corrosion and washdown affect enclosure, cooling and terminal protection.
VFDs improve control but introduce braking energy, low-speed cooling and insulation compatibility checks.
Without datasheets, the buyer cannot verify duty, torque, insulation or equivalent substitution.
A quote with kW only is incomplete. Request duty, torque, insulation, enclosure, brake/control compatibility and datasheets for each motion.